Primer and probe synthesis
Primer and probe synthesis

Primer and probe synthesis

DIA-UP BIO has advanced automated production equipment and quality testing equipment, which can meet the requirements of different customers for large-scale and high-throughput synthesis of products. It adopts the commercial industrial production process of oligoglycosides and strictly controls the entire production process according to the ISO13485:2016 quality management system, ensuring stable and high-quality primer and probe synthesis services for customers.


  • Product Introduction
  • Product Features
  • FAQ/Experimental Cases
  • Manual Download

DIA-UP BIO has advanced automated production equipment and quality testing equipment, which can meet the requirements of different customers for large-scale and high-throughput synthesis of products. It adopts the commercial industrial production process of oligoglycosides and strictly controls the entire production process according to the ISO13485:2016 quality management system, ensuring stable and high-quality primer and probe synthesis services for customers.


Product TypeModifier TypeProduct TypeModifier Type
Single label probe classLNA(bp)Double labeled probes5′ FAM 3′ TAMRA
DI(bp)5′ FAM 3′ BHQ1
DU(bp)5′ FAM 3′ Dabcy1
Thio substitution(bp)5′ FAM 3′ MGB
Spacer C3(bp)5′ FAM 3′ Eclipse
Spacer 9(bp)5′ HEX 3′ BHQ1
Spacer 12(bp)5′ HEX 3′ TAMRA
Spacer 18(bp)5′ HEX 3′ Eclipse
dSpacer 5′ HEX 3′ Dabcy1
dT-C6-Amino5′ HEX 3′ MGB
5′ -sulfydryl5′ ROX 3′ BHQ2
5′ NH2 C65′ ROX 3′ MGB
NH2 C125′ Cy5 3′ BHQ2
3′  NH2 C75′ Cy5 3′ BHQ3
5′ -Phosphorylation5′ Cy5 3′ MGB
3′ -Phosphorylation5′ Cy5.5 3′ BHQ3
5′ Biotin5′ TET 3′ BHQ1
3′ Biotin5′ TET 3′ TAMRA
5′ FAM5′ VIC 3′ Dabcy1
3′ FAM5′ VIC 3′ BHQ1
5′ HEX5′ VIC 3′ TAMRA
5′ TET5′ VIC 3′ MGB
5′ TAMRAMiddle dt marker classdT-FAM
3′ TAMRAdT-ROX
5′ ROXdT-TAMRA
3′ ROXdT-Dabcy1
5′ Cy3dT-Cy3
3′ Cy3dT-Cy5
5′ Cy5Single label probe class3′ -Dabcy1
Cy5.55′ -Dabcy1
3′ Cy53′ BHQ1
5′ VIC3′ BHQ2

3′ddA/ddT/ddC/ddG

3′ BHQ3
5′rapp3′ eclipse

3′ -MGB


1. Strict quality standards: QC testing items cover five aspects: appearance, quantification, molecular weight, purity, fluorescence excitation/emission wavelength, etc;

2. Industrial production customization: can provide high purity primers and ultra pure primers exclusive to large OD/g grade IVD;

3. Rich types of modification: including special modified bases, thio modification, phosphoric acid modification, interstitial spacers, amino modification, thiol modification, biotin, Digoxin, fluorescent labeling, quenching group, electrochemical labeling, etc.

NO

No Data

Related Recommend